Gas wall-mounted boiler ariston bs 24 ff. Heating systems for country and country houses

  • 18.10.2019

Characteristics and operation of the boiler Ariston BS ii 24 ff

The double-circuit gas boiler Ariston BS 24 FF is a versatile and compact mini-boiler room containing all the necessary components.

Wall mounted boiler used for heating small spaces with an area of ​​50-240 m2, in which it is impossible to install a floor heating device, as well as for supplying an object hot water.

Rice. 1. Control panel of the gas wall-mounted boiler Ariston BS ii 24 ff

1. Green LEDs showing temperature and alarms, 2 . ON/OFF button, 3. Green LED ON/OFF, 4. Manometer (pressure in the heating circuit), 5. Yellow LED for signaling anomalies in the smoke exhaust system, 6. Summer/winter switch - Heating system temperature controller, 7. Hot water temperature controller, 8. Socket for programming timer (option), 9. Red LED - dispenser operation blocking signal, 10. Reset / Function button chimney cleaning, 11. Red LED for overtemperature alarm

Rice. 2. General form gas wall boiler Ariston BS 24ff

1. Flue gas outlet, 2. Pressure switch, 3. Condensate trap, 4. Primary heat exchanger, 5. Overheating thermostat, 6. Heating circuit flow temperature sensor, 7. Burner, 8. Ignition electrodes, 9. Ignition device, 10 Gas valve, 12. Heating circuit safety valve (3 bar), 13. Secondary heat exchanger, 14. Drain cock, 15. DHW flow sensor, 16. Make-up cock, 17. Heating circuit filter, 18. Circulation pump with air vent , 19. Heating return temperature sensor, 20. Three-way valve actuator, 21. Flame control electrode, 22. Mineral fiber combustion chamber thermal insulation panel, 23. Combustion chamber, 24. Expansion tank, 25. Fan, 26. Point analysis of combustion products

Technical specifications gas boiler Ariston BS ii 24 ff

Rated thermal power for the heating circuit, no more / no less than (Hi) kW - 25.8 / 11.0

Rated thermal power for the heating circuit, not more / not less than (Hs) kW - 28.7 / 12.2

Output heat output (heating mode), no more / no less than kW - 24.2 / 9.8

Fuel combustion efficiency (measured at the outlet of combustion products), Hi / Hs% - 94.5

Efficiency at rated power (60/80 °C), Hi/Hs % - 93.8 / 84.5

Efficiency at 30% of nominal power (47 °C), Hi/Hs% - 93.6 / 84.3

efficiency per minimum power, Hi/Hs% - 89.2 / 80.3

Heat loss through the chimney with the burner on % - 5.5

Heat loss through the chimney with the burner off % - 0.4

Residual pressure in the circuit Pa - 100

Flue gas temperature (G20) °C - 105

The amount of combustion products, not more than (G20) m3 / h - 56.8

Excess air % - 72

Maximum hydraulic resistance (dT=20°C) mbar - 200

Residual pressure in the circuit bar - 0.25

Expansion tank pressure bar - 1

Maximum pressure in the circuit bar - 3

Expansion tank volume l - 8

Water temperature in the heating circuit, not more / not less than ° C - 85 / 35

Water temperature in the DHW circuit, not more / not less than °C - 60 / 36

Flow rate in the DHW circuit (after 10 min at dT=30 °C) l/min - 11.3

Flow rate in the DHW circuit at dT=25 °C l/min - 13.6

Flow in the DHW circuit at dT=35 °C l/min - 9.7

Water consumption in the DHW circuit, not less than l / min - 1.7

Pressure in the DHW circuit, no more than bar - 7

Voltage and frequency V/Hz - 230/50

Power consumption W - 92

Protection class °C +5

Weight kg - 30

Dimensions (W x H x D) mm - 400/770/315

Commissioning of the gas boiler Ariston BS ii 24 ff

To turn on the boiler, press the on/off button on the control panel.

Power supply - Make sure that the voltage and frequency in the power supply network correspond to those indicated on the nameplate of the wall-mounted boiler Ariston BS 24 ff.

Gas supply:

Make sure that the type of gas in the system corresponds to that indicated on the boiler nameplate.

Open windows and doors.

Make sure there are no open flames or sources of sparks.

Check the gas burner part of the gas wall-mounted boiler Ariston BS ii 24 ff for leaks. To do this, with the gas supply valve closed (switched off), close and reopen the main gas valve. Within 10 minutes, the meter should not register gas flow.

Filling the heating circuit:

Open the air valves on the radiators of the heating circuit.

Raise the cap of the automatic air vent of the circulation pump.

Gradually open the boiler feed valve and close the air valves on the radiators of the heating circuit until water starts to come out.

When the pressure according to the pressure gauge reaches 0.1 - 0.15 MPa (1 - 1.5 bar), turn off the boiler feed valve.

First commissioning

Make sure that:

The main gas valve is closed.

Electrical connections completed. Check again that the green (yellow) wire is connected to a good ground.

Lift the cap of the automatic air vent of the circulation pump with a screwdriver.

Make sure that the pressure in the system (as indicated by the manometer) is greater than 1 bar.

Turn on the column (by pressing the on / off button) and select the stand-by mode, there is no request for either domestic hot water or the heating system.

Start the venting cycle by pressing the MODE button for 10 seconds. The column will begin an evacuation cycle of approximately 7 minutes.

At the end, check whether the air is completely removed from the heating circuit, if not, repeat the cycle.

Bleed air from radiators.

Open the supply valve cold water, wait until the air is completely bled from the circuit.

The chimney must be properly sized and free of obstructions for the removal of combustion products.

Make sure that the necessary ventilation holes in the room are open (they should be in a type B installation).

Open the gas valve, check all seals for tightness: the meter should not show gas flow. Repair if there are leaks.

Start the Ariston BS 24 ff boiler in winter (heating) or summer (DHW) operating mode.

Automatic forced air removal mode

To start the mode, press and hold the MODE button for 10 s. The duration of the cycle is approximately 7 minutes.

To interrupt the cycle, press the MODE button. If necessary, the cycle can be restarted.

First make sure that the boiler is in standby mode, i.e. without supply to the DHW and heating circuits.

Checking gas parameters

Dismantle the front decorative panel and lower the control panel of the boiler Ariston BS ii 24 ff.

Inlet pressure check:

Loosen the screw and insert the pressure gauge connection tube into the pressure tap.

Run the boiler on maximum power in the “Chimney sweep” mode (press the RESET button and hold for 10 s, the display in position 27 shows “L- - “). The gas inlet pressure must correspond to the nominal for this type of gas.

After 10 minutes or by pressing the button again, the boiler exits the "Chimney sweep" mode.

Checking the maximum power of the gas wall-mounted boiler Ariston BS 24 ff:

To check the maximum power, loosen the screw and connect the manometer tube to the pressure tap.

Start the boiler in the “Chimney sweep” mode: press the RESET button and hold for 10 s, the display shows “L- - “; for the boiler to operate at maximum DHW output, press the 1 + button. The display shows “L- - “.

The gas pressure at the inlet must correspond to that indicated for this type of gas in the summary table of parameters, depending on the type of gas. Otherwise, remove the protective cap and tighten or loosen the adjusting screw.

After checking, tighten the screw and make sure it is tight.

Replace the protective cap of the regulator.

The boiler exits the "Chimney sweep" mode automatically after 10 minutes or immediately by pressing the RESET button.

Checking the minimum power of the gas wall-mounted boiler Ariston BS 24 ff:

To check the minimum power, loosen the screw and connect the manometer tube to the pressure tap.

Disconnect the combustion chamber compensator tube.

Start the boiler in the "Chimney sweep" mode: press the RESET button and hold for 10 s. The display shows "t". To make the boiler work at minimum power, press button 1 +.

The display shows "L- - ".

Disconnect the wire from the pressure regulator (modulator).

The gas pressure at the inlet must correspond to that indicated for this type of gas in the summary table of parameters, depending on the type of gas. Otherwise, adjust it with a screw.

After checking, tighten the screw and make sure it is tight.

Connect the wire to the pressure regulator.

Connect the compensator tube.

The Ariston BS ii 24 ff boiler exits the “Chimney sweep” mode after 10 minutes automatically or immediately by pressing the RESET button.

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

_______________________________________________________________________________

__________________________________________________________________________

OPERATION AND REPAIR OF BOILERS

Gas boilers Ariston appeared on the Russian heating market among the first. Thanks in large part to its worldwide famous brand, this Italian manufacturer of gas heating equipment quickly managed to “win over” a domestic buyer and achieve high sales dynamics.

Ariston gas boiler, reviews of the owners of which help to better decide on a purchase, we can often find on different sites and in online stores. Modern feature set and good design, not bad specifications and a large selection of models are a clear advantage when buying a device, even despite the somewhat inflated prices.

But today we will consider not only the pros, but also the disadvantages of Ariston mounted boilers, having studied their device and features of the models, using the instruction manual, photos, customer and specialist reviews.

Model range of wall-mounted double-circuit gas boilers Ariston

The Italian manufacturer is represented on Russian market a fairly wide range of wall-mounted gas boilers. We can meet Ariston double-circuit and single-circuit gas boilers, traditional and condensing, with storage boiler and without it.

In addition, like most competitors, gas boilers heating Ariston are issued with the closed combustion chamber (turbocharged) and with open (atmospheric). For devices with forced draft, a chimney outlet is provided horizontally through the wall, additionally buying a special one for it with a pipe diameter of 60/100 mm.

Gas boilers Ariston: product range


To date, the Italian company produces several modifications of its traditional double-circuit gas boilers:

- Ariston BS 15 FF, 24 FF and 24 II;

- Ariston Cares X 15 CF and 15 FF, 18 FF, 24 CF and 24FF;

- Ariston HS 15 CF and 15 FF, 18 FF, 24 CF and 24FF;

- Ariston Clas X 24 FF, 28 FF and 24 CF;

- Ariston Egis Plus and Premium;

— Ariston Genus X;

— Ariston Alteas X.

The single-circuit gas boiler Ariston with the possibility of connecting an indirect heating boiler is represented by only one model “Ariston Cares X System” with a power of 15 to 32 kW with closed and open combustion chambers.

Double-circuit gas boilers Ariston are available with a capacity of 15, 18, 24 and 28 kW. The most popular modification is a 24 kW device that can heat a house up to 200-230 m2. Turbocharged boilers have the symbols FF in their name, atmospheric - CF.

Features of the Ariston Cares X gas boiler: instructions, device

Ariston Cares X 24FF


This model is one of the budget ones in the price segment up to 35,000 rubles, and due to this, the most popular, judging by the number of reviews from the owners of the Ariston boiler. But even for a small amount, the buyer receives a modern wall-mounted gas boiler with a nice appearance, button control and LCD display, as well as the entire set of necessary functions.

As on all models of Ariston wall-mounted gas boilers, the Cares X series devices are equipped with: circulation pump stamps Wilo with automatic air vent and gas valve SIT. In addition, they are equipped with a boiler safety group and a membrane expansion tank for 8 liters.

The gas boiler "Ariston Cares X" has two heat exchangers: the main copper with aluminum coating for the heating circuit and the compact secondary stainless steel for the DHW circuit. The capacity of this secondary heat exchanger for the 24 kW Ariston Cares X 24 FF (CF) models is 13.6 l/min. Consider the device of a double-circuit gas boiler Ariston Cares X 24 FF NG:

Double-circuit gas boiler Ariston


1 - outlet for a coaxial chimney;
2 - pneumatic relay;
3 - collector for condensate;
4 - main heat exchanger for heating;
6 and 19 - temperature sensors at the inlet and outlet of the heating circuit;
7 - Polidoro gas burner;
8 - ignition electrodes;
9 - secondary heat exchanger for hot water supply;
10 - gas valve SIT;
11 - safety valve for 3 bars;
12 - ignition block;
13 - pressure gauge;
14 - tap for feeding the heating system;
15 - filter;
16 - DHW flow sensor;
17 - Wilo circulation pump;
18 - pressure switch;
20 - three-way valve drive;
21 - burner flame control sensor;
22 - combustion chamber;
23 - expansion tank;
24 - fan (turbine).

The "winter-summer" mode and room thermostat help to reduce gas costs. In summer, the boiler can only work on the DHW circuit, while in winter the device works economically thanks to the modulating gas burner. The room thermostat is not included in the boiler, but it can always be purchased separately.

Boilers of this series have in their device temperature sensors installed on the "supply" and "return", running water temperatures, flame and draft control sensors. In addition, the devices are equipped with a security system: protection against low water pressure, protection against freezing of the system and its overheating.

The Ariston gas boiler is adapted to Russian conditions, such as power surges, low gas pressure and low air temperature outside the window. But, even despite this, the manufacturer himself recommends connecting the boiler through.

This recommendation applies not only to boilers of this brand, but also to other wall-mounted gas boilers of any manufacturer. If the electronic board of the boiler suddenly fails due to a power surge, then this case will not be guaranteed.

Technical characteristics of the double-circuit gas boiler Ariston Cares X

Ariston gas boiler: technical specifications


Advantages of Ariston gas boilers:

- a very large selection of models;
- a prestigious global brand;
- Italian assembly;
- two heat exchangers;
— adaptation to Russian conditions.

Disadvantages of gas boilers Ariston:

- overcharge;
- components made in China;
- the main direction of the company is the production of storage water heaters.

Dual circuit gas boilers Ariston

The Ariston trademark, under which high-quality household and, in particular, heating equipment is produced, is today the property of the Italian concern Indesit Company. This brand combines the proven traditions of the past with the innovations of the future. All this makes Ariston appliances the perfect solution to ensure maximum comfort in your home.

At present, the production divisions of Ariston and Hotpoint are merged into one functional structure. The result was a joint trademark, which is steadily gaining momentum in popularity both in Europe and in Russia.

A special place of honor among the assortment of Hotpoint-Ariston is occupied by water-heating boilers, which, perhaps, are the pride of the Italian company. The units supplied to the world market are ergonomic and stylish design. It would seem, how can you make an ordinary design not only functional, but also visually attractive? Italian engineers from Hotpoint-Ariston were able to do this.

The undoubted advantage of Hotpoint-Ariston boilers can also be considered the fact that they differ high level safety and ease of daily use. They are also distinguished from competitors by their quiet operation, which is also very important, especially when installing heating equipment in a small apartment, where every sound can cause discomfort.

Hotpoint-Ariston designers strive to diversify the appearance of the proposed designs as much as possible, so that the buyer has the opportunity to choose exactly the model that harmoniously fits into the concept of a particular interior. Now it is not at all necessary to hide the water heating unit in a specially designated place, since the Hotpoint-Ariston boiler looks very stylish and concise.

The technique of the Italian brand is a unique combination of elegance, reliability and manufacturability. An important plus of Hotpoint-Ariston boilers is their environmental safety. And even if this quality is not valued by the Russian consumer as highly as by the European, a loyal attitude towards environment confirms the manufacturer's desire for continuous improvement of each unit of the model range.



Ariston has a lot of achievements in its long history. Founded in the 1930s as a family business, today it can safely be called one of the leaders in its industry. Today, products offered under the Ariston brand rank third in their market segment in terms of sales. The main activity of this functional division of Indesit is the production household appliances medium and high price segment.

If we talk about heating equipment offered on the domestic market under the Hotpoint-Ariston brand, then first of all it is worth mentioning BS type water heating boilers. It is this technique that is in deserved demand all over the world, due to its efficiency and performance. Moreover, each of the models in the BS line has small size and weight, which greatly facilitates the process of their transportation and installation. An obvious plus of these heating boilers is also that they are equipped with separate heat exchangers. Separately, it is worth mentioning the reliability of the built-in hydraulics, which can withstand aggressive operating conditions without any problems.

Let us consider in more detail the most popular modification of equipment in this line - the boiler Ariston bs 24 ff

The gas boiler Ariston bs 24 ff is a high-performance wall-mounted 2-circuit type unit that can be used simultaneously for hot water and heating. Among the offers on the market, this equipment can be considered the most attractive, since it combines technical excellence, durability and affordable price.

Experts recommend installing Ariston bs 24 ff as universal remedy for heating apartments and private houses. This technique allows significant cost savings. family budget for heating, when compared with the central water supply system. By purchasing an Ariston bs 24 ff boiler, you can forget about the cold weather even at unusually low temperatures outside the window. Italian brand equipment is able to maintain comfort in your home at all times.

Benefits Ariston models bs 24 ff the following are worth noting:

  • Adaptability to work in difficult Russian conditions. The technique easily copes with lowering the gas pressure in the system to a level of 5 mbar. In addition, the boiler continues to function even with water pressure drops in the circuit, which is also very important for our country. Ariston bs 24 ff is adapted to power surges due to the presence of a special protection system.
  • The boiler is able to maintain operation even at very low temperatures outside the window (up to -52 degrees Celsius).
  • The presence of an analog control panel, which displays the temperature of the coolant in the system.
  • The possibility of distributing the intensity of the heating system without affecting the water heating system.
  • Electronic flame modulation.
  • Protection of the boiler against scale.
  • Pump blocking prevention system.
  • Prevention of freezing of the coolant in the system in case of a decrease in the air temperature outside the window.
  • Ariston bs 24 ff is able to independently diagnose a problem and adequately respond to its occurrence.

The Ariston boiler will please the buyer with the presence of a copper heat exchanger and a secondary plate heat exchanger made of stainless steel. The specialists of the manufacturing company took care of the durability of the equipment, equipping it with a durable stainless steel burner that can maintain stable operation for decades.

As additional structural advantages, it is worth noting the elements hydraulic system, made of durable materials, 3-way valve with actuator, two temperature sensors and two filters for mechanical cleaning of the coolant.

Ariston bs II 24 ff

Ariston bs II 24 ff is a reliable 2-circuit wall-mounted gas boiler with a closed firebox. A separate heat exchanger increases the efficiency of the entire system and extends the life of the equipment. The useful power of this unit is 25 kW, which is enough to heat an apartment or a small country house, whose area does not exceed 240 square meters. Wherein Maximum temperature coolant in the heating system reaches 85 degrees Celsius.

The equipment is highly productive. Ariston bs II 24 ff is capable of producing 13.6 liters hot water per minute at 25 degrees. A coefficient useful action reaches 93%. For this class equipment such a high efficiency is a worthy indicator.

The device is easy to install, so it is not necessary to entrust this task to specialists. If you are confident in your own skills and want to mount Ariston bs 24 ff on your own with the instructions that come with the equipment, you can easily do it.

But do not forget that an experienced specialist with one hundred percent probability will be able to install the equipment without any errors, which will protect you from the possible withdrawal of equipment from warranty service, for which the manufacturer has full right in case of violation of any rules. The instructions for Ariston bs 24 ff are clear and comprehensive enough for the wizard to cope with the installation without problems.

When choosing heating equipment, pay attention to equipment from world-famous brands. A striking example of this are wall-mounted gas Ariston boilers. They are used for heating private cottages, apartments in apartment buildings, commercial and industrial facilities. Their power is up to 35 kW, which corresponds to maximum area 350 sq. m. Ariston also produces more powerful models.

Features and benefits of Ariston wall-mounted gas boilers:

  • Reliable heat exchangers made of copper and steel;
  • Many models for any operating conditions;
  • Intuitive control;
  • Low level noise;
  • High energy efficiency.

Ariston wall-mounted gas boilers are assembled with steel and copper heat exchangers. The latter are characterized by higher resistance to corrosion and thermal stress. The heat exchangers used do not require excessively frequent maintenance and please with a long service life.

Ariston boilers are represented by many models with one or two circuits. Single-circuit models are the simplest in the line of heating equipment. They heat the rooms, giving them warmth. Double-circuit models are a little more complicated, but provide consumers with hot water. Ariston wall-mounted gas boilers are distinguished by efficient DHW circuits, quickly heating water to the desired temperature. The most powerful models can work with several draw-off points. Boilers are also divided into atmospheric and turbocharged. The latter are designed to work with a coaxial chimney, they are equipped with fans for the forced removal of combustion products. To create comfort, low-noise fans are used here.

Management in these boilers is extremely simple. The consumer needs to set the temperature in the heating and water supply circuits - no additional actions are needed. The equipment will provide support for the specified temperature regime and heats the water in the DHW circuit to the specified value. For support certain temperature in the rooms you need to connect a thermostat. Advanced models use weather-dependent automation and climate control modules via Wi-Fi and the Internet.

Ariston wall-mounted boilers are characterized by high efficiency, reaching 94%. Almost all the heat generated by them is sent to the heating system - with a minimum amount of losses. Using these boilers for heating residential, industrial and commercial buildings, you can count on solid gas savings.

Looking for where to buy wall-mounted gas boilers from Ariston? You will find them in the Teplodvor online store catalog. Customers can choose from models with a power of up to 35 kW, with open and closed combustion chambers, as well as with one and two circuits. Select equipment using the parameters filter, order delivery in Moscow and Russia.