Malfunctions of Ariston gas boilers and instructions for their elimination. Why Ariston wall-mounted gas boilers are good: a detailed review Gas boiler ariston bs ii 24 ff

  • 18.10.2019

For high-quality heating of the premises of private houses of medium size (250-300 m²), the Ariston BS24FF boiler, operating on natural gas, is perfect. This is a fairly reliable product of a well-known Italian brand, which is distinguished by an acceptable cost. Unfortunately, the instruction manual attached to it rather briefly describes the device and functions of the heating unit, so it is worth considering them in more detail.

General overview of the heat generator

domestic hot water device Ariston BS II 24 FF is a gas wall-mounted heat generator equipped with a closed combustion chamber and forced combustion air supply by means of a fan (suction). Due to this organization of fuel combustion, the efficiency of the unit is 93.8% in normal mode and 89.3% with minimal combustion. To remove flue gases from the house, a double-walled coaxial chimney is used.


Theoretically, the rated power of the boiler is 25.8 kW, which is enough to service the water heating system of a private cottage with an area of ​​​​up to 300 m², located in middle lane Russian Federation and properly insulated. With poor insulation or lack thereof, the power of the device is enough to heat no more than 250 m² of area.

The Ariston BS 24 gas boiler is a modern multifunctional unit that can operate in automatic mode and does not need constant supervision by the homeowner. In addition, it is equipped with a second heating circuit for preparing water for the needs of hot water supply.

As the instruction says, the device includes the following main components and elements:

  1. Controller. This is the electronic brain of the boiler, which controls its operation based on the readings of temperature, pressure and draft sensors, as well as signaling the current mode or malfunction.

  2. Burner device of modulating type. It can smoothly change the intensity of combustion at the command of the controller, thereby adjusting the power of the heat generator.
  3. primary heat exchanger. Serves for heating water in the heating network.
  4. secondary heat exchanger. Heats tap water for domestic hot water.
  5. Safety gas valve. Shuts off the gas supply independently of the controller when a emergencies. These include a drop in fuel pressure in the line below 5 mbar, the disappearance of draft in the chimney and spontaneous extinction of the burner.
  6. Closed combustion chamber, insulated with basalt fiber.
  7. A fan that supplies air to the chamber and removes flue gases from there through a coaxial chimney.

In addition to the main elements, the Ariston BS 24 FF boiler is equipped with additional devices that turn it into a wall-mounted mini-boiler room.

This circulation pump, equipped with an automatic air vent, and a membrane-type expansion tank with a capacity of 8 liters. The heat generator heats water for heating up to a temperature of 85°C, for hot water supply - up to 60°C. The operating pressure range in the heating system is from 0.6 to 1.5 bar, the maximum is 3 bar.


The maximum pressure for which the DHW circuit is designed is 7 bar. The wall-mounted boiler is able to provide water consumption for household needs up to 10 l / min when it is heated by 35 ° C.

Functions of the thermal unit

The wall-mounted gas boiler Ariston is equipped with many functions, which allows you to operate it with maximum comfort:

  • convenient front panel with indicators operating temperature and a pressure gauge showing the pressure in the heating network;
  • electric ignition, carried out in automatic mode;
  • protection against power surges in the network, freezing and the appearance of a layer of scale;
  • adaptability to Russian operating conditions at low gas pressure;
  • smooth change of burner operating modes (modulation), which allows burning fuel with maximum efficiency;
  • the possibility of switching to liquefied gas;
  • the unit is equipped with a container for collecting condensate flowing from the secondary heat exchanger when heating water for domestic hot water;
  • Possibility of connection of weather-compensated automation and room thermostat.

For the manufacture of elements of the heat generator, appropriate materials were used to ensure a long service life. The heating heat exchanger is made of copper and has an additional protective coating, the hot water treatment unit is made of stainless steel. The burner is also made of stainless steel and protected from clocking (frequent shutdowns).

Starting and running the heater

The instruction manual for the Ariston boiler says that to start it, just press the "ON" button, the controller of the device will do the rest. If after 10-12 seconds the start did not occur, then it is necessary to reset it with the "Reset" button and repeat the inclusion. A repeated unsuccessful start means that the automation does not allow switching on due to a malfunction. According to the instructions, you need to contact the service department, but some problems can be detected on your own:

  • low pressure in the heating network;
  • the heating system is filled incorrectly, there are air pockets in the boiler;
  • electrical network failures.

In accordance with the rules, the connection of a gas heating unit to the gas main and a test run must be carried out by specialists of an organization that has a permit for these types of work. Therefore, the first inclusion should not cause you problems.

After the burner is turned on, heating of the coolant begins up to the temperature set by the regulator on the front panel. If the faucet is opened at this time hot water, then the flow sensor in the boiler will work, and the three-way valve will switch the coolant flow to the second heat exchanger. The water in the DHW circuit will heat up to the temperature set by the second regulator.

1. Pipe for the exit of combustion products
2. Pressure switch
3. Condensate trap
4. Primary heat exchanger
6. Temperature sensor on the flow to the heating circuit
7. Burner
8. Ignition electrodes
9. Gas valve
10. Ignition device
12. Safety valve heating circuit (3 bar)
13. Secondary heat exchanger
14. Drain valve

16. Make-up tap
17. Heating circuit filter
18. Circulation pump with air vent
19. Relay min. Pressure
20. Temperature sensor on the return from the heating circuit
21. Three-way valve actuator
22. Flame control electrode
23. Heat-insulating panel of the combustion chamber
mineral fiber
24. Combustion chamber
25. Expansion tank
26. Fan
27. Point of analysis of combustion products

Hydraulic circuit

1. Fan
2. Primary heat exchanger
4. Water temperature sensor on the supply to the heating circuit
5. Burner
6. Ignition electrodes
7. Gas valve
8. Secondary plate heat exchanger
9. Safety valve 0.3 MPa (3 bar)
11. Automatic bypass
12. Drain valve
13. Make-up tap
14. Heating circuit filter
15. Flow sensor in the DHW circuit
16. Three way valve
17. Pressure gauge
18. Relay min. Pressure
19. Circulation pump with automatic
air vent
20. Flame control electrode
21. Expansion tank
22. Water temperature sensor on the return line of the circuit
heating
23. Flue gas pressure switch (pressure switch)

Characteristics and operation of the boiler Ariston BS ii 24 ff

The double-circuit gas boiler Ariston BS 24 FF is a versatile and compact mini-boiler room containing all the necessary components.

Wall mounted boiler used for heating small spaces with an area of ​​50-240 m2, in which it is impossible to install a floor heating device, as well as for supplying an object with hot water.

Rice. 1. Control panel of the gas wall-mounted boiler Ariston BS ii 24 ff

1. Green LEDs showing temperature and alarms, 2 . ON/OFF button, 3. Green LED ON/OFF, 4. Manometer (pressure in the heating circuit), 5. Yellow LED for signaling anomalies in the smoke exhaust system, 6. Summer/winter switch - Heating system temperature controller, 7. Hot water temperature controller, 8. Socket for programming timer (option), 9. Red LED - dispenser operation blocking signal, 10. Reset / Function button chimney cleaning, 11. Red LED for overtemperature alarm

Rice. 2. General form gas wall boiler Ariston BS 24ff

1. Flue gas outlet, 2. Pressure switch, 3. Condensate trap, 4. Primary heat exchanger, 5. Overheating thermostat, 6. Heating circuit flow temperature sensor, 7. Burner, 8. Ignition electrodes, 9. Ignition device, 10 Gas valve, 12. Heating circuit safety valve (3 bar), 13. Secondary heat exchanger, 14. Drain cock, 15. DHW flow sensor, 16. Charging cock, 17. Heating circuit filter, 18. Circulation pump with air vent , 19. Heating return temperature sensor, 20. Three-way valve actuator, 21. Flame control electrode, 22. Mineral fiber combustion chamber thermal insulation panel, 23. Combustion chamber, 24. Expansion tank, 25. Fan, 26. Point analysis of combustion products

Technical specifications gas boiler Ariston BS ii 24 ff

Rated thermal power for the heating circuit, no more / no less than (Hi) kW - 25.8 / 11.0

Rated thermal power for the heating circuit, not more / not less than (Hs) kW - 28.7 / 12.2

Output heat output (heating mode), no more / no less than kW - 24.2 / 9.8

Fuel combustion efficiency (measured at the outlet of combustion products), Hi / Hs% - 94.5

Efficiency at rated power (60/80 °C), Hi/Hs % - 93.8 / 84.5

Efficiency at 30% of nominal power (47 °C), Hi/Hs% - 93.6 / 84.3

efficiency per minimum power, Hi/Hs% - 89.2 / 80.3

Heat loss through the chimney with the burner on % - 5.5

Heat loss through the chimney with the burner off % - 0.4

Residual pressure in the circuit Pa - 100

Flue gas temperature (G20) °C - 105

The amount of combustion products, not more than (G20) m3 / h - 56.8

Excess air % - 72

Maximum hydraulic resistance (dT=20°C) mbar - 200

Residual pressure in the circuit bar - 0.25

Expansion tank pressure bar - 1

Maximum pressure in the circuit bar - 3

Volume expansion tank l - 8

Water temperature in the heating circuit, not more / not less than ° C - 85 / 35

Water temperature in the DHW circuit, not more / not less than °C - 60 / 36

Flow rate in the DHW circuit (after 10 min at dT=30 °C) l/min - 11.3

Flow rate in the DHW circuit at dT=25 °C l/min - 13.6

Flow in the DHW circuit at dT=35 °C l/min - 9.7

Water consumption in the DHW circuit, not less than l / min - 1.7

Pressure in the DHW circuit, no more than bar - 7

Voltage and frequency V/Hz - 230/50

Power consumption W - 92

Protection class °C +5

Weight kg - 30

Dimensions (W x H x D) mm - 400/770/315

Commissioning of the gas boiler Ariston BS ii 24 ff

To turn on the boiler, press the on/off button on the control panel.

Power supply - Make sure that the voltage and frequency in the power supply network correspond to those indicated on the nameplate of the wall-mounted boiler Ariston BS 24 ff.

Gas supply:

Make sure that the type of gas in the system corresponds to that indicated on the boiler nameplate.

Open windows and doors.

Make sure there are no open flames or sources of sparks.

Check the gas burner part of the gas wall-mounted boiler Ariston BS ii 24 ff for leaks. To do this, with the gas supply valve closed (switched off), close and reopen the main gas valve. Within 10 minutes, the meter should not register gas flow.

Filling the heating circuit:

Open the air valves on the radiators of the heating circuit.

Raise the cap of the automatic air vent of the circulation pump.

Gradually open the boiler feed valve and close the air valves on the radiators of the heating circuit until water starts to come out.

When the pressure according to the pressure gauge reaches 0.1 - 0.15 MPa (1 - 1.5 bar), turn off the boiler feed valve.

First commissioning

Make sure that:

The main gas valve is closed.

Electrical connections completed. Check again that the green (yellow) wire is connected to a good ground.

Lift the cap of the automatic air vent of the circulation pump with a screwdriver.

Make sure that the pressure in the system (as indicated by the manometer) is greater than 1 bar.

Turn on the column (by pressing the on / off button) and select the stand-by mode, there is no request for either domestic hot water or the heating system.

Start the venting cycle by pressing the MODE button for 10 seconds. The column will begin an evacuation cycle of approximately 7 minutes.

At the end, check whether the air is completely removed from the heating circuit, if not, repeat the cycle.

Bleed air from radiators.

Open the supply valve cold water, wait until the air is completely bled from the circuit.

The chimney must be properly sized and free of obstructions for the removal of combustion products.

Make sure that the necessary ventilation holes in the room are open (they should be in a type B installation).

Open the gas valve, check all seals for tightness: the meter should not show gas flow. Repair if there are leaks.

Start the Ariston BS 24 ff boiler in winter (heating) or summer (DHW) operating mode.

Automatic forced air removal mode

To start the mode, press and hold the MODE button for 10 s. The duration of the cycle is approximately 7 minutes.

To interrupt the cycle, press the MODE button. If necessary, the cycle can be restarted.

First make sure that the boiler is in standby mode, i.e. without supply to the DHW and heating circuits.

Checking gas parameters

Dismantle the front decorative panel and lower the control panel of the boiler Ariston BS ii 24 ff.

Inlet pressure check:

Loosen the screw and insert the pressure gauge connection tube into the pressure tap.

Run the boiler on maximum power in the “Chimney sweep” mode (press the RESET button and hold for 10 s, the display in position 27 shows “L- - “). The gas inlet pressure must correspond to the nominal for this type of gas.

After 10 minutes or by pressing the button again, the boiler exits the "Chimney sweep" mode.

Checking the maximum power of the gas wall-mounted boiler Ariston BS 24 ff:

To check the maximum power, loosen the screw and connect the manometer tube to the pressure tap.

Start the boiler in the “Chimney sweep” mode: press the RESET button and hold for 10 s, the display shows “L- - “; for the boiler to operate at maximum DHW output, press the 1 + button. The display shows “L- - “.

The gas pressure at the inlet must correspond to that indicated for this type of gas in the summary table of parameters, depending on the type of gas. Otherwise, remove the protective cap and tighten or loosen the adjusting screw.

After checking, tighten the screw and make sure it is tight.

Replace the protective cap of the regulator.

The boiler exits the "Chimney sweep" mode automatically after 10 minutes or immediately by pressing the RESET button.

Checking the minimum power of the gas wall-mounted boiler Ariston BS 24 ff:

To check the minimum power, loosen the screw and connect the manometer tube to the pressure tap.

Disconnect the combustion chamber compensator tube.

Start the boiler in the "Chimney sweep" mode: press the RESET button and hold for 10 s. The display shows "t". To make the boiler work at minimum power, press button 1 +.

The display shows "L- - ".

Disconnect the wire from the pressure regulator (modulator).

The gas pressure at the inlet must correspond to that indicated for this type of gas in the summary table of parameters, depending on the type of gas. Otherwise, adjust it with a screw.

After checking, tighten the screw and make sure it is tight.

Connect the wire to the pressure regulator.

Connect the compensator tube.

The Ariston BS ii 24 ff boiler exits the “Chimney sweep” mode after 10 minutes automatically or immediately by pressing the RESET button.

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

_______________________________________________________________________________

__________________________________________________________________________

OPERATION AND REPAIR OF BOILERS

BS gas heating boilers are the best equipment for those who understand economy. The 24 kW wall-mounted boiler for heating and hot water supply is compact in size, light in weight, has two reliable separate heat exchangers and a unique hydraulic group.

The new equipment is distinguished by an affordable price, which makes it an extremely attractive product on the heating market.

Recommended for apartment heating and hot water supply in high-rise city buildings. Its use will reduce the cost of each consumer for heating (in comparison with the existing central heating) by about 2-3 times. Having your own boiler, you decide when and what temperature it needs to maintain in the apartment. Individual comfort, perfect value for money!

Main benefits:

    fully adapted for Russia - work at reduced gas pressure (up to 5 mbar), low pressure and water flow;

    resistance to voltage drops;

    built-in condensate collector;

    operation at low outdoor temperature (up to -52°С)

    analog control panel with temperature display

    the possibility of reducing the power for heating (with the same power for hot water) and the function of switching on delay

    function of continuous electronic modulation of the burner flame

    anti-freeze, scaling and blocking functions of the circulation pump and 3-way valve

    self-diagnosis function

    primary heat exchanger made of copper with a protective coating,

    secondary stainless steel plate heat exchanger

    durable stainless steel burner with safety feature

    heavy-duty composite hydraulic group, motorized three-way valve

    2 ultra-precise ntc temperature sensors

    2 mechanical cleaning filters - in the heating and hot water circuit

    expansion tank 8 l.

    self-diagnosis function

    Possibility to connect t-control and room thermostat

The Ariston Egis 24 FF gas boiler is one of the most successful models manufactured by an Italian company with a worldwide reputation. For a number of reasons, this unit is in surprising demand from buyers both in Russia and in other countries. Let's try to figure out why this seemingly inconspicuous unit attracts consumers so much.

Gas boiler Ariston Egis 24 FF series

Egis 24 FF was developed and launched on the market in 2007. This boiler is equipped with a closed combustion chamber, as indicated by the letters FF characteristic of Ariston units. The device is a unique combination of technical excellence, decent working qualities and ease of use. In addition, reliability is an essential feature of the Egis 24 FF from Ariston.

This model is a hinged wall-mounted boiler, which is characterized by small dimensions of 400x770x315 millimeters and a weight of 30 kg. All this, of course, greatly simplifies the installation of equipment in a small apartment.

Low fuel consumption is one of the most important distinguishing features Ariston Egis 24 FF, which is why many buyers prefer this particular model. In addition, this device boasts such an advantage as adaptability to the features of almost any heating system. Due to its small dimensions, its installation and aggregation with a gas duct and water fittings is noticeably simplified.

Market experts note that the Egis 24 FF model is ideal for both primary installation and as a replacement for an old unit with a new one. Installers manage to get the equipment working even in very difficult conditions.

Among the additional advantages inherent in this boiler, the following can be noted:

  • Exquisite minimalistic appearance. The boiler can be harmoniously integrated into almost any interior, whether it is an expensively decorated bathroom, a plumbing unit or a utility room.
  • Well thought out interface. Everything in Egis 24 FF is made in such a way that the user gets the maximum pleasure from controlling the equipment, without experiencing the slightest irritation or discomfort.
  • High speed of response of thermal sensors to any changes in external parameters.
  • Removing errors using special indicators.

Ariston Egis 24 FF is equipped with a copper heat exchanger. By the way, it has a special protective anti-corrosion coating. The design of the heat exchanger is such that the transfer of thermal energy from the burning fuel to the water in the circuits is as efficient as possible. All units of this model are equipped with a Polidoro burner, which has managed to prove itself well among specialists.

Hidden fittings and low level the noise emitted during operation can also be considered important advantages of Italian technology trademark. The design also provides for the presence of an antifreeze system that prevents the coolant from freezing in conditions of low temperature outside the window.



Scale protection is a very important option for a Russian buyer. This is because the quality of the coolant in our country is not so good as to refuse such an additional guarantee of a long service life of equipment. It is also worth noting that the 3-way valve and the circulation pump are reliably protected from sticking.

Ariston of the Egis 24 FF series is capable of operating in the "Chimney sweep" mode, which allows you to evaluate combustion products. The company offers a huge selection of optional accessories for temperature control.

The nominal output of the Egis 24 FF boiler is 24.6 kW. At the same time, the efficiency of the system reaches 94.1%. The water temperature in the heating circuit ranges from 40-82 degrees Celsius. At the same time, in the DHW system, the temperature of the coolant is from 36 to 60 degrees, depending on the intensity of the equipment.

There is also an updated version of the popular boiler - Ariston Egis PLUS 24 FF. The rated power of the unit is 24 kW. His distinguishing feature– the ability to function at a gas pressure in the system from 5 mbar. The design also provides for the presence of two high-precision NTC temperature sensors. As an option, the device can be aggregated with the T-CONTROL system.

The presence of a built-in condensate collector increases the efficiency of the equipment. The device is able to function even at very low temperatures outside the window (in practice, up to -52 degrees Celsius).

Egis PLUS 24 FF has two filters for mechanical cleaning of the coolant. Another feature of the unit is the ability to work together with a solar collector.

Installation Features

This unit is fairly quick and easy to install. Via Ariston instructions Egis 24 FF can be done by almost anyone who has ever dealt with gas burner equipment. All electrical connections are accessible from the outside, which is very convenient.

If you are not confident in your abilities and skills, entrust installation of Ariston Egis 24 FF series to a professional who can not only mount the unit with high quality, but also correctly configure its operation depending on your needs for heat and hot water.

Give preference to this technique in the process of choosing the optimal heating unit, and you will never regret your decision.