Proterm gas boiler how to operate. Boiler start-up and shutdown Boiler adjustment – ​​Operating Instructions PROTHERM Medved KLZ

  • 20.06.2020

9

Boiler start

Warning: Putting the boiler into
operation and its first start-up should
be produced only by certified

Protherm specialist
specialized organization!

When starting the boiler for the first time, make sure
in that:

1. the boiler is connected to the electrical network and

while the phase and zero are not reversed.

2. the gas shut-off valve is open;
3. service taps for heating and hot water supply

4. The pressure in the heating system is

within acceptable limits of 1 - 2 bar.
Install the main switch (Fig. 1,
pos. 7) to the ON position (I). Boiler
turn on and start working
heating water in the boiler (if the boiler
connected to the boiler). After heating the water in
boiler, the boiler will switch to the mode
heating (provided that the mode
heating is active). In the event of a protective

boiler shutdown on the panel display
control will display a message about
faults (see "Messages about
errors”, page 8). With button
RESET (fig. 1, pos. 6) unlock
boiler. If, after switching on, the protective
shutdown will be repeated, or not possible
will unblock the boiler,
contact a service organization.

Boiler shutdown

When the boiler is switched off for a short time
install the main switch (Fig.
1, pos. 7) to the OFF (O) position.
When the boiler is turned off for a long time
period you need to turn it off
electrical network and shut off the supply
gas to the boiler. If in winter period boiler
not used, the heating system
needs to be emptied. but
frequent drains should be avoided and
replenishment of the heating system to avoid
scaling and deposits inside
boiler.

Starting and shutting down the boiler

Boiler adjustment

Operation of the boiler without room
regulator


according to the readings of the boiler sensor. V
terminal block XT5 on terminals 5 and 6 is
jumper (factory setting). Order
settings:

Turn on the boiler with the main switch;
set the desired temperature

supply line on the control panel.

Boiler operation with room temperature
thermostat

In this mode, the boiler supports
set temperature in the heating system
according to the room regulator. Jumper,
mounted in terminal block XT5 on clamps
5 and 6 are removed. In its place is connected
room regulator. If indoors
with room regulator on radiators
thermostatic valves installed
must be converted to full
open position.
Warning: On the control panel

Meaning

Malfunction on-
hand sensor
temperature

The boiler works without restrictions, but the temperature

The heating medium is controlled by the boiler sensor (see
"Setting the heating temperature", page 5).

If the boiler does not work in equithermal mode, then
such a message cannot appear.

__________________________________________________________________________

Installation, connection and start-up of the boiler Proterm Panther

Mounted gas boiler Proterm Panther 25 KTV with forced exhaust of combustion products and model 25 KOV with natural exhaust, running on natural gas or propane, are designed for heating and hot water supply country houses, cottages, small garden buildings, utility buildings and other facilities that are equipped with a heating system with forced circulation of the coolant and water supply.

Fig.1. Hinged gas boiler 25 KTV PANTHER

1 - closed (sealed) combustion chamber (turbochamber); 2 - atmospheric type burner; 3 - heat exchanger; 4 - circulation pump; 5 - air vent; 6 - heat exchanger of the DHW system; 7 - three-way valve drive; 8 - gas valve; 9 - ignition electrodes; 10 - control electrode; 11 - ignition unit; 12 - control panel; 13 - heating temperature sensor; 14 - emergency temperature sensor; 15 - thrust sensor; 16 - fan; 17 - water pressure sensor

The boiler is designed for operation in the temperature range from +5 to 40 °C and relative humidity up to 85%.

The temperature of the outer surfaces of the boiler unit (side and top covers) during boiler operation must not exceed the ambient air temperature by no more than 50°C.

When placing the boiler, it is not allowed to place objects near it:

From flame-retardant materials - at a distance of less than 100 mm from the surface;

From flammable materials, such as fibreboard, polyurethane, lightweight PVC, synthetic fibres, rubber, etc. - at a distance of less than 200 mm from the surface.

A free space of at least 1m must be left in front of the boiler for maintenance work.

At the Protherm Panther 25 KTV boiler, the removal of combustion products and the supply of combustion air is carried out by a special coaxial pipeline or separate pipelines.

From standard parts, you can make a coaxial chimney for almost all laying options. The length of the chimney, the type and number of sections must be agreed with the service organization.

The chimney must be laid in such a way that the condensate from the combustion products can be removed. For this, special sections are designed that are built into the chimney route.

The gas boiler Proterm Panther 25 KOV is designed to discharge combustion products into a natural draft chimney. The boiler is connected to the chimney using a pipe with a diameter corresponding to the size of the chimney pipe.

It is not allowed to install objects in the pipe that restrict the passage of combustion products (for example, different kinds heat recovery heat exchangers, etc.).

Installation gas boiler Proterm Panther

The Protherm Panther 25 KTV (KOV) boiler should be installed in closed heating systems with water as the heat carrier. The nominal pipe diameter of the system is selected based on the characteristics of the pump. The pipeline is designed according to the required capacity of this system, and not the maximum
boiler heat output.

In this case, the flow rate of the coolant must be such that the temperature difference between the supply and return is no more than 20 ° C. The minimum flow rate of water in the system is 500 l/h. The piping system must be designed in such a way as to ensure the removal of air from it.

The air vents are located on the high place in the system and on all radiators. The heating system is filled to a pressure of at least 1 bar. The recommended pressure range in the system is 1.2 - 2 bar.

Expansion tank The boiler is designed for a heating system capacity of 95 liters. In larger systems, another membrane-type expansion tank should be installed. Heating radiators can be equipped with thermostatic valves.

If the unit is controlled by a room regulator, thermostatic valves are not installed in the room where the room regulator is located. Before installation, the system must be thoroughly cleaned.

DHW system

The water pressure in the DHW system must be in the range of 1 - 6 bar. If the pressure exceeds 6 bar, a pressure reducing valve must be installed on the inlet. If the hardness of the tap water is high, it is recommended that appropriate measures be taken to reduce it.

Connection pipes have external threads. They must not be loaded with the weight of the pipes of the heating system, the DHW system or the gas supply. The installation dimensions of the connecting pipes (height, distance from the wall and between individual inlets and outlets) must be exactly observed.

In the lower part of the boiler there is a hydraulic group, which is equipped with a safety relief valve, a valve for filling (filling) the system and a drain valve. If the maximum pressure in the system (2.5 kgf/cm2) is exceeded, water may flow out of the safety relief valve or steam may be released.

Connecting the boiler to heating system it is recommended to carry it out in such a way that during its repair it is possible to drain the water only from the unit. Make-up of the heating system (in small quantities) can be carried out using the make-up tap.

The drain valve is designed to reduce the water pressure in the boiler during possible repairs. It is possible to drain water from the boiler with this tap only partially. Complete draining of water or the entire heating system, as well as re-filling, must be carried out using valves (plugs) for filling and draining installed in
certain places in the heating system.

Filling the Protherm Panther boiler and system with water should be done in the following order:

Check that the pressure in the DHW system is higher than the water pressure in the heating system.

Carefully open the filling cock in the hydraulic group and at the same time monitor the pressure increase on the boiler pressure gauge. The faucet is opened by turning counterclockwise, clockwise - closes.

Upon reaching required pressure the filling valve must be closed carefully and check whether the water pressure rises (the valve must be fully closed).

If the DHW pressure in the water supply is the same or lower than the pressure in the heating system, water may leak into the water supply, which is unacceptable. This can be prevented by setting check valve on the water supply pipe to the boiler.

During repairs, unfavorable building layouts, etc., it is possible to connect the boiler to the heating system, DHW system and gas supply with special flexible hoses.

When using flexible hoses, they must have a length of no more than 0.5 m, protected from mechanical stress and damage, exposure to aggressive substances. At the end of the service life of the hoses, they must be replaced with new ones. To connect the boiler to the pipeline from copper pipes you can use a special connecting set of shaped copper pipes with fittings.

Tube dimensions:

OV inlet and outlet - tube diameter 22 mm.
- DHW inlet and outlet - tube diameter 15 mm.
- Gas connection - tube diameter 22 mm.
- Connection safety valve– tube diameter 22 mm.

Gas connection

Size 25 KTV (KOV) - ZP is designed to operate on natural gas with a nominal pressure in the distribution network of 1.8 kPa and a calorific value of 35900 kJ/m3. Pipe diameter, fittings and gas meter must be selected taking into account other gas appliances of the consumer. A pipe with a minimum connecting diameter of 1/2“ must be connected to the boiler, but preferably with a nominal diameter of 3/4“.

Size 25 KTV (KOV) - P is designed to operate on liquefied gas (propane), with a calorific value of 12.3 to 13.0 kWh/kg.

Due to the fact that the operation of the boiler with the use of cylinders is problematic, first of all, from the point of view of ensuring a sufficient number of them, as well as their further use, provides for the simultaneous use of a gas tank near the heated facility and its filling by an authorized organization.

Calculations required sizes propane supply from the gas tank to the boiler unit or to other gas appliances are part of the project and delivery of the gas tank. With the help of a gas pressure reducing valve, it is necessary to ensure the nominal gas pressure in front of the boiler is 3.0 kPa.

Air supply and removal of combustion products

Air is supplied and exhaust products of combustion are carried out through an external coaxial pipeline? 100 mm. Equivalent length of the pipeline (numerically equal to the sum running meters straight pipe and number of 90° elbows) should be no more than 9 m. If the equivalent length of the pipeline is more than 3 m, the throttle disc must be removed from the fan outlet.

Horizontal sections of the pipeline must be installed with a slope of at least 1.5% towards the flue gas outlet so that condensate flows out of the pipeline. Condensate drains are used in vertical sections.

The outlet of the pipeline must be located:

At a height of at least 2 m from the foundation of the building in places visited by people and at least 0.4 m - in places not visited by people;

At a distance of at least 0.5 m horizontally from windows, permanently open ventilation grills and doors;

Above the upper border of windows, bars or doors;

In the area under awnings, balconies and roof edges.

Minimum distance between two adjacent pipe outlets:

Horizontally - 1 m;
- vertically - 2 m.

The direction of the pipe exit should be oriented so that the combustion products go out into the open space.

The horizontal distance from the end of the outlet of the pipeline on one facade to the other, with the opposite placement of outlets, should be:

2 m if there are no windows or bars on one facade;

1 m if both facades are without windows or bars;

4 m if both facades have windows or bars (or if there are adjacent exits on the same facade).

In the niche of the facade of the building, the distance between the axis of the pipeline outlet and the adjacent plane of the facade should be:

2 m if there are windows or bars on the facade;
- 0.5 m - if they are absent.

All distances are given from the outer border of the window (grille) or door to the axis of the pipeline. In the space under the canopy (balcony), the pipe head must be at a distance of at least the radius of the circle.

With a vertical exit of pipelines to the roof, their heads should be placed at a distance of at least 0.4 m horizontally and at a height of at least 0.4 m from the roof surface, taking into account its shape.

The chimney outlet must not be placed in an explosive area, in internal parts buildings or structures, tunnels or underpasses, in enclosed spaces.

A hole in the wall for the passage of a coaxial pipeline is made with a certain gap (from 10 to 15 mm). Upon completion of installation, the gap is insulated with non-combustible materials ( polyurethane foam, gypsum, plaster).

Electrical connection of the gas boiler Proterm Panther

The Proterm Panther boiler must be connected to the mains through a socket with a grounding contact, which eliminates the zero-phase connection error. The distance from the boiler to the socket must be within the length of the boiler power cord (1m).

The boiler must be connected to protective conductor(grounding). The ground conductor must be accessible for inspection and resistance testing.

It is not allowed to use various tees, extensions, etc. for the electrical connection. The boiler is protected against overload and short circuit by fuses P1 -T80 mA/250V, P2 - T 1.6 A/250V installed in the control panel. Before working on the electrical equipment of the boiler, it is necessary to disconnect the boiler from the mains by disconnecting the electrical plug from the socket.

To control the boiler from a room regulator, use a regulator with a potential-free output (except for the mains voltage, it is not allowed to supply any other voltage to the boiler). Connect the room regulator to the unit with a flexible two-wire cable with a cross section of 0.5 to 1.5 mm2. Exit the cable from the boiler through a plastic cable gland.

The terminal block for connecting the room regulator and the external sensor is located at the bottom, inside the boiler and is accessible after removing the outer cover and turning the control panel. Before connecting, the jumper must be removed from the terminal block. The minimum load on the output contacts of the regulator is 24 V / 0.1A.

The outside temperature sensor should be connected with a two-wire copper conductor with a cross section of 0.75 mm2. Wiring resistance should be no more than 10 ohms, the maximum length is 30 m.

The circuits for connecting the outside temperature sensor and the room thermostat must not be laid together with the mains voltage circuits.

Commissioning of the Protherm Panther boiler:

Remove the screw securing the cover to the bottom of the boiler;

Tilt the cover down (towards you) and lift it off the pins at the top of the camera.

Make sure the gas supply is closed.

Loosen the cap on the automatic air separator located on the pump.

Connect the boiler to the electrical network.

Turn the power switch to position “I”. The display will show code F0, the pump will run for approximately 1 minute.

Press the Bar/Mode button. The display will show 0.0 (pressure value) and the LED will light up.

The pressure value is displayed for about 25 seconds. The display then returns to its original position. The pressure value can be displayed again by pressing the Bar/Mode button.

Fill the system with water, the pressure should be between 1.2 and 2 bar.

Carefully bleed all heaters (water flow should be continuous, without air bubbles).

Leave the cap on the air separator loosened during boiler operation.

Open the DHW taps to remove air from the DHW circuit;

Check that the pressure shown on the display is in the range of 1.2 - 2 bar, top up if necessary.

Starting the boiler Proterm Panther

Before starting the boiler check:

The main gas supply valve is open,
- the gas valve at the inlet is open,
- closing valves (water, heating) on exit open,
- the unit is connected to the mains.

To start the Protherm Panther boiler, do the following:

Switch the power switch to position “I”;

Set the extract air temperature to 85 °C and turn off the equithermal control (E-).

Check the condition of the room regulator (it must be closed);

Slowly raise the temperature in the heating system to the maximum (all radiators must be with open valves). The air in the water of the heating system is gradually removed through an automatic air separator. In the high point system and radiators must be free of air;

Make up the system to a pressure of 1.2 bar;

Switch on the boiler again and heat the system up to the maximum temperature;

Turn off the boiler, if necessary, remove the air and re-feed the system with water;

Make sure that after the heating system has cooled down, the pressure gauge shows at least 1.2 bar;

If the pressure in the heating system in the heated state is higher by. 0.5 bar than when cold, check the setting of the expansion vessel in relation to the system.

Protective functions of the boiler Proterm Panther

The boiler is equipped with a frost protection function. When the temperature drops below 10 °C, the pump will automatically turn on. When the temperature drops below 8 °C, the machine will fire up and work until the temperature rises by 25 °C. In case of freezing (the temperature of the RH is below 3 °C), the start of the boiler is blocked.

The pump switches on automatically for a short time if it has not been switched on for 24 hours. This provides protection against blocking due to deposits during a long shutdown. The pump runs continuously when the temperature rises above 85°C (overheating protection).

When the pressure drops, the LED flashes, when the pressure drops further, the unit goes out (protection against water loss - alarm F0). When the pressure rises, work automatically resumes.

The protective functions are activated only when the boiler is connected to the mains voltage (the electric cord is in the socket and the mains switch is in the on (I) position).

If the boiler has been disconnected from the mains voltage for a long time (a month or more), it is recommended to start it periodically (at least once a month). The boiler is equipped with a safety valve. When discharging heating water from the valve, turn off the boiler and disconnect it from the mains voltage.

Boiler adjustment Protherm Panther

When the boiler is operating without a room regulator, it maintains the temperature set on the display.

Adjustment operations:

– select the equithermal regulation mode – select the heating curve and set the symbol E-;

– select the equithermal regulation mode – in the option of parallel movement, put the symbol P-;

– select the EXH temperature mode and adjust it;

– the room regulator must be switched off, a jumper must be installed between the terminals for its connection.

When the Proterm Panther boiler is operating with a room regulator, it maintains the temperature set on the display. In this case, the unit is switched off by the commands of the room thermostat installed inside the control room. This room should not have a thermostatic valve on the radiator.

During installation, the jumper is removed from the boiler terminals and the room thermostat is connected. When operating in equithermal mode, the temperature changes depending on the change in the outside air temperature.

An external air temperature sensor must be connected to the boiler. The sensor is installed on the coldest wall of the building (north or northwest) at a height of about 2.5 - 3 m. The sensor should not be located in the area of ​​ventilation emissions from windows or other ventilation devices
and exposed to direct sunlight.

Inlet gas pressure control:

Switch off the boiler.

Loosen the screw on the pressure measurement fitting of the gas valve;

Connect an appropriate pressure gauge;

Carry out a launch;

Check the inlet gas pressure, if it is below normal, check the tightness of the gas pipeline;

Turn off the unit and disconnect the pressure gauge, carefully tighten the screw on the measuring point and check its tightness.

if you have Vacation home, and communications are not connected to it, then you can solve the issue, expressed in the need for a heating device and providing water heating, with the help of boiler equipment. The main thing is to make right choice, because such an installation will occupy a central place in the house and the heating system. The choice should be made, guided by the rules of safety and reliability.

Modern heating equipment is offered in a huge range. You can choose a floor or wall model, with or without a chimney, non-volatile or powered by electricity. Modern manufacturers offer for sale single-circuit and double-circuit options for heating equipment. The former will be able to make the house more comfortable and cozy, while the latter will allow you to use hot water. Before making a choice, you need to read the reviews, Proterm boilers are no exception to this rule. They are offered in a wide range, can have different capacities and specifications, you can read about it below.

Overview of boilers from the manufacturer "Proterm": "Bear 50 KLZ"

This model of equipment costs 143,914 rubles. It is a gas floor boiler that can run on main fuel. The consumer will have the opportunity to provide connection to liquefied gas. The equipment is double-circuit and is used for heating, as well as for hot water supply. The design has an open combustion chamber.

To remove combustion products, a fan must be connected. This Proterm Bear boiler has a 10-liter expansion tank. The heat exchanger is based on cast iron, which increases the reliability of operation and the life of the boiler. The manufacturer made sure that the unit was protected from overheating of the coolant in the system. To do this, the engineers provided the model with a cooling circuit. Convenient start-up of the device is provided by electric ignition.

Considering the model of heating equipment "Bear 50 KLZ", it can be mentioned that it has a power equal to 49 kW. The burner is modulating. The maximum power consumption is 50 kW. Gas temperature at minimum and maximum power is equal to 115°C.

You may also be interested in how liquefied gas is consumed, the value is 3.8 kg per hour. The heating temperature is equivalent to 85°C. At 25°C of the coolant, the productivity reaches 21 liters per minute. If the dimensions of the boiler room are limited, then you should ask about the design parameters, they are 1385x505x892 mm. The device weighs 210 kg. It belongs to the X4D protection class. The volume of the expansion tank is 10 liters.

The temperature of the heating medium at the outlet can reach up to 70 °C. The possible pressure of natural gas is 0.013 bar. The maximum consumption of natural gas is 35.2 m 3 / h. If you plan to connect the equipment on your own, then you may need a chimney diameter, which is 180 mm. At 100% thermal power, the efficiency of the equipment is 92%.

Reviews about the model

The above-described heating boiler "Proterm", according to consumers, has many positive features, among them should be highlighted:

  • simple control;
  • high efficiency;
  • independent regulation of thermal loads;
  • the possibility of replacing the middle cast iron sections.

As for the ease of operation, it is provided by an external panel with which you can adjust and control the parameters of the floor model. Consumers emphasize that this equipment is used for systems with closed coolant circulation.

The device is controlled by a built-in microprocessor. Buyers, in their words, quite often choose this model for the reason that it provides the ability to independently adjust the heat loads of the hot water and heating circuit. The unit is also good because it is resistant to complex hydraulic conditions.

User manual

After you get acquainted with the characteristics of the Proterm boiler that you bought or are just planning to purchase, it will not be out of place to ask what operating rules the manufacturer prescribes. Quite often, this allows you to extend the life of the equipment or eliminate its breakdown. As for the model described above, it must be installed only in rooms specially equipped for this.

Commissioning of the device is carried out only after testing. It is important to follow the safety rules. They say that gas supply standards must be taken into account. You can independently set the temperature of the water in the boiler. This also applies to the heating temperature. In this case, the operator will have to use the MODE button.

To set the time intervals for heating water in the boiler, use the timer. The operation of the Proterm gas boiler is also convenient because on the panel you can see equipment messages about errors that occur during operation. For example, if you see the code F1, it will indicate a loss of flame. But the designation F2 indicates that the boiler temperature sensor turned out to be faulty.

Overview of the wall-mounted boiler brand "Gepard 23 MTV"

Another option for equipment from the manufacturer Proterm is Gepard 23 MTV. You can buy this model for 42,088 rubles. The device was developed in 2015 and is used for heating and hot water supply.

The design provides for a closed combustion chamber, which makes it possible to use a coaxial chimney. The boiler has a copper primary heat exchanger. The burner is made of chromium-nickel steel. The heat exchanger in the device is lamellar, it is made of stainless steel.

Specifications

The above boiler "Proterm Cheetah" has a power equal to 24.6 kW. Power consumption reaches 156 watts. Buyers are often interested in the maximum consumption of natural gas, it is 2.9 m 3 / h. The outlet hot water temperature can reach 65°C, while its minimum value is 35°C. Permissible natural gas pressure 0.02 bar. The volume of the expansion tank is 5 liters.

The equipment belongs to the X4D protection class. The unit weighs 34 kg, this should be taken into account, because the Proterm wall-mounted boiler must be securely fixed on a vertical surface. The flue gas temperature is 110°C. The maximum fuel consumption when using liquefied gas is 2.1 kg per hour. The heating temperature can reach 83°C, while the minimum value is 35°C. If you plan to install the device in cramped conditions, then the dimensions of the unit should be of particular interest to you, they are equal to 740x310x410 mm.

Among the main advantages of the above-described equipment option, consumers distinguish:

  • closed combustion chamber;
  • equipped with a coaxial exhaust gas system;
  • the ability to receive information about the operation of the boiler using a liquid crystal display;
  • automatic switching to hot water mode when a hot water tap is opened.

If we compare this model with the previous one in the line, then it was equipped with a display by the manufacturer. Its bright backlight allows the user to see data even in a bright room. The boiler is durable and reliable, which is ensured by a hydraulic block made of composite material. This feature has improved the model compared to the previous generation, where the units were equipped with hydroblocks.

User manual

Instructions for the Proterm boiler are included in the kit. This is very convenient, because immediately after purchase you can familiarize yourself with it in order to avoid mistakes when using the device. If the boiler is not used for its intended purpose, this may lead to a danger to human health and life. If during the operation of the equipment you notice a strong smell of gas, you should open the doors and windows wide, creating a draft. Do not use open flames or smoke while doing this, and do not turn on power plugs, telephones and other intercoms in the building.

Explosive or flammable substances such as paper, gasoline and paint should not be stored or used in the same room as the boiler. Sufficient air supply must be ensured for combustion. Protective devices do not need to be removed and shunted during operation of the equipment. It is not recommended to perform any manipulations with protective systems.

Overview of the boiler brand "Panther 35 kW"

This gas boiler "Proterm" has an affordable cost, which is 63398 rubles. The equipment is a two-circuit unit with a closed combustion chamber. The device provides for the presence of a primary heat exchanger and a plate heat exchanger for hot water supply, which is made of stainless steel. The liquid crystal display is located on the outer panel, which allows the operator to see the data even in a bright room. The risk of freezing is reduced, as is overheating thanks to additional safety features.

Model specifications

After reviewing the reviews of the Proterm boilers, you can understand which model is better to choose. But it is also important to take into account the technical characteristics. For example, the Panther model has a power of 35 kW. Power consumption reaches 175 watts. The flue gas temperature at minimum power is 102.9°C. This traditional boiler provides a maximum power input of 38.4 kW.

Electric boiler Proterm The slope for heating is the most common model in Russia among all manufacturers on the domestic market. Good quality European assembly and reliability of components, many positive feedback on electro Protherm boilers and reasonable prices contributed to their popularity among buyers, both in Russia and abroad.

To understand the advantages and disadvantages of Slovak heating equipment, it is necessary to analyze the technical characteristics and design of wall-mounted electric boilers Proterm of the Skat series, the model range on the market, and connection features. We will also consider problems and malfunctions that may arise during the operation of the device, errors and methods for their elimination.

Model range of electric boilers Proterm Skat, type K (KR)

To date, the Slovak company "Protherm" is represented at Russian market not only with its boilers, but also with eight models of electric boilers of the Skat K (KR) type, which differ in power consumption and connection to the electrical network. The country of origin of water heaters is Slovakia.

The company produces only single-circuit devices capable of heating private house with a total area of ​​30 to 280 m2. Among them, both single-phase - with the ability to connect to a 220 V power supply, and three-phase - 380 Volts stand out.

Electric boiler Proterm: photo


The main difference between electric boilers of this model range is their nominal power, which can be 6 or 9 kW, 12, 14 or 18 kW, 24 and 28 kW. Depending on the model chosen, these are the units:

- low power: Skat 6K and 9K;
- medium power: Skat 12K, 14K and 18K;
- high power: Skat 21K, 24K and 28K.

The operation of the Proterm electric boiler is controlled using special buttons, made in the form of multidirectional arrows, on the front panel of the heating apparatus.

They can set the required water temperature in the heating system, as well as in a remote indirect heating boiler, which is purchased if it is necessary to obtain hot water for household needs. In addition, the button " Mode/Ok» you can turn on (set) the desired mode of operation of the electric boiler:

- traditional mode for heating (25-85 ° С);
- "warm floor" mode (30-45 ° С);
- the mode of preparation of hot water in an indirect heating boiler (35-70 ° C).

The multifunctional LCD display informs about the temperature in the heating circuit and the boiler, as well as about problems and errors in the operation of the boiler in case of any malfunctions. Above the display there are lights that light up depending on the set operating mode of the device, changes in power consumption and insufficient water pressure in the system.

By default, all Protherm electric boilers are 3-phase, however, low-power models of 6 and 9 kW (Skat 6K and Skat 9K) can be connected to a single-phase 220 V network. Medium power devices are designed for heating houses up to 180 m2, and high-power boilers - more than 20 kW can be installed in private houses or other premises with a total area of ​​up to 280-300 m2. We look at the table.

Proterm Skat: cable cross-section, energy consumption


Features of the electric boiler device Proterm

The heating apparatus consists of several main elements necessary for its full operation.

1. Cylindrical copper heat exchanger for heating the coolant.
2. Block of heating elements made of copper different power and quantity with multi-stage switching.
3. Expansion tank 7 liters to compensate for thermal expansion in the heating system.
4. Hydraulic group consisting of:

- three-speed circulation pump ;
- 3 bar safety valve;
- automatic air vent.

In addition, an NTS temperature sensor is installed on the heating circuit line, as well as an emergency sensor that protects the unit from overheating. There is a system for protecting the device from freezing. and from blocking the circulation pump.

Electric heating elements are mounted in the heat exchanger of the Proterm boiler, from above and below. Depending on the model, the number of heating elements may be different. For example, in the Skat 6K, 9K, 12K and 14K devices, two blocks of heating elements are installed, in Skat 18K and 21K - three heating elements, in 24K and 28K - four. For each model, the blocks of heating elements have different capacities.

I propose to disassemble in detail the internal structure of the Proterm Skat mounted electric boiler according to the instruction diagram:

Internal device "Protherm Skat" according to the instructions


1 - heating unit;
2 - valve for air release;
3 - heat exchanger;
4 - pressure sensor;
5 - safety valve;
6 - regulator for setting the circulation pump;
7 - pump status LED;
8 - grounding on the "return";
9 - grounding on the body of the water heater;
10 - pump for circulation;
11 - connection of the electric cable;
12 - contactor;
13 - electronic board;
14 — temperature sensor NTS;
15 - emergency temperature limiter.

Electric boiler connection: water circuit, cable

Connecting an electric boiler Protherm


1. Like most modern, wall-mounted heaters, all connectors for connecting the boiler are located at the bottom of the body. This is done to save space in the room where the electric boiler is installed.

2. The heating water circuit is connected using two 3/4″ threaded fittings. On the left is the return line (heat carrier inlet to the boiler), on the right is the straight line (outlet).

3. Nearby are: an overflow for a safety valve, a drain valve, as well as connectors for connecting electric cable different section. You can monitor the pressure in the heating system according to the pressure gauge, which is also located in the lower part of the device.

Electric boilers Proterm Skat: specifications, dimensions

Proterm boilers have rather compact dimensions of 410 x 740 x 310 mm, which allows them to harmoniously fit into the interior of even a very small kitchen or boiler room. See the table for other specifications.

Technical characteristics of electric boilers Proterm


Errors and malfunctions of the Proterm electric boiler: troubleshooting methods

1. Error code F00, F10, F13, F19.

These codes tell us about a malfunction of the NTS temperature sensor. You may need to replace it or replace the electronic board. But first, check the cable connections for operability.

2. Error F20.

The emergency temperature limiter or thermal fuse is defective. Try shorting them one by one. If the boiler shuts down again, replace the defective element.

3. Error F22.

This error indicates a "dry" start of the electric boiler. Add water pressure to the system, it must be at least 0.6 bar. Air may also be present in pipes and radiators.

4. Error code F41 and F55. A relay or contactor has stuck. Check these parts for defects.

5. Error F63. No connection to EEPROM. Reset the settings to factory settings.

6. Errors F73 and F74.

Errors under these codes indicate problems with the water pressure sensor. You need to check the contacts or replace the sensor itself.

7. Errors F85 and F86. Freezing of water in the electric boiler itself (F85) or in the indirect heating boiler (F86).

Wiring diagram for boilers Proterm Skat

Wiring diagram for connecting the boiler Proterm Skat 6, 9, 12, 14K


Advantages of electric boilers Proterm:

— build quality and reliability in operation;
— a wide range of different power;
modern system security;
— high efficiency of 99.5%;
- the ability to connect additional options and equipment;
good feedback buyers and professionals.

Disadvantages of the Proterm brand electric boiler:

- lack of a room apparatus in the configuration;
- there are no models with a built-in boiler for heating domestic water;
- it is not allowed to use antifreeze liquid as a coolant;
- price from 35,000 rubles.

We have examined in detail electric boilers Proterm Slope for heating, the entire range and specifications. Having disassembled the internal device according to the operating instructions, we revealed the main advantages and disadvantages of these devices. They also turned their attention to possible mistakes in case of malfunctions and some ways to fix them yourself. Let's watch the video.

If it is not possible to connect to the gas network, and solid fuel heating is not available, then alternative way providing the house with heat becomes an electric boiler. This article will introduce readers to the Proterm Skat electric boilers, as well as instruct them on how to launch them.

Electric boilers Proterm Skat

This single-circuit equipment is made in a wall-mounted variation. It is possible to connect a water heater. Most models three-phase mains connection required, but models with a power of 6 kW and 9 kW can be operated from a 220 V network. The choice of the required level of temperature for hot water and heating occurs using the display, which, when adjusted, helps to control the operation of the equipment. Also, control is carried out using a thermostat or an outside temperature sensor.

To create a certain level of warmth, the parameters are adjusted individually. Power supply is controlled remotely from the tariff meter. For domestic needs, you can install units of 24 kW and 28 kW in a cascade.

Protherm Skat has:

  • double-sided pump;
  • expansion tank;
  • safety valve;

Also, the Protherm boiler can be connected through a voltage stabilizer. Electric boiler in action has a slow start, that is, for two minutes it "accelerates" and its power is minimal. Heating elements are protected from overload, their work is uniform, this is achieved by the possibility of setting the rhythm (1.2 or 2.3 kW).

Protherm Skat electric boilers are distinguished by their low weight (only 34 kg) and convenient dimensions, which makes it possible to install on almost any area. The operation of the boiler is reliably protected by several functions:

  • pump blocking protection;
  • a pressure sensor that monitors the level of water pressure;
  • frost protection;
  • protection against valve blocking and freezing of the water heater (when connecting a boiler).

If errors occur in the operation of the boiler, automatic diagnostics occur, ending with the display of the results in the form of a code. The deciphering of the codes is given in the instruction manual for the product.

Advantages and disadvantages of Protherm Skat electric boilers

Proterm Skat has a number of advantages over other types of heating:

  • does not carry out harmful emissions into the atmosphere, since has no combustion products, so this type of heating can be called environmentally friendly;
  • electric boiler - accessible view heating. It is used where it is not possible to connect to the mains gas or can become an alternative form of heating;
  • does not need systematic maintenance, unlike, for example, gas or solid fuel models;
  • silent operation;
  • there is a heat level regulator;
  • able to adapt to domestic water of poor quality;
  • resistant to voltage drops;
  • equipped with several types of protection.

Along with the advantages, there are some disadvantages:

  • electric boiler Protherm Skat needs to be connected through a stabilizer;
  • not able to perform its work when the mains power is turned off.

Consumer reviews

Consumers note that Protherm Skat provided an opportunity where gas connection was problematic or even impossible. With the stable operation of the power grid, many refuse to connect gas, saving considerable amounts of money. In addition, the electric boiler is used in parallel with the gas unit, connecting them to unified system heating. This find allows significant savings on resources, alternating them with each other during the heating season.

If you connect a water heater to Protherm Skat, consumers will have the prospect of using hot water. Many note the perfectly designed design of the boiler, which fits well into any interior of the room. It can be successfully installed in living rooms, thanks to its silent operation, it will not cause increased attention to itself.

The disadvantages are that when using only a boiler powered by electricity, when it is turned off, there are no alternative heating options. Therefore, before making a purchase of a Protherm electric boiler, you should make sure that there are no problems with electricity. Experts recommend use a voltage stabilizer, to ensure the normal operation of the Protherm Skat boiler.

In addition, the increased energy consumption of the electric boiler causes negative emotions among the population, since paying bills hits the pocket. If we compare the costs of gas and electric heating, then the Protherm electric boiler costs a little more, with identical heating parameters. From the foregoing, we can conclude that this electrical equipment is chosen by those who do not have the ability to connect to the mains gas, as well as those who care about environment and sees it as a source of ecological consumption.

How to put the Protherm Skat boiler into action?

To start the boiler, follow the instructions below.

When the pressure is reduced, the “bar” light starts flashing on the display. To correct the situation, water should be added to the system. If in this case the pressure decreases, then you need to contact a specialist.

If you want to stop the operation of the Protherm boiler for a long time, then you need to disconnect it from the power supply and turn off the taps. If you need to stop during the winter, then water must be drained from the system to prevent freezing.

How to take care of the Protherm electric boiler? Do not use abrasives or chemicals. Better surface case wipe wet wipe then dry the surface.

Any malfunctions are shown on the display with an error code. Code numbers are located and deciphered in the product passport.

If serious problems occur, such as the heat exchanger is frozen or water is dripping from it, it is forbidden to turn on the electric boiler to the power supply. You need to wait for a specialist who will diagnose and make quality repair. Parts can only be replaced with original spare parts.

So, dear readers, you got acquainted with an alternative type of heating Protherm Skat. When gas and solid fuel out of reach or you are an adherent of cleanliness, an electric boiler can be a good help.