Ariston 24 ff turbine device. Why are Ariston wall-mounted gas boilers good: a detailed review

  • 18.10.2019

The Italian trade mark Ariston, behind which a well-known world manufacturer is hidden household appliances Indesit Company has been designing and manufacturing gas heating boilers since the mid 70s of the last century.

The structural division of Indesit Company is the Ariston Thermo Group, whose gas boilers have gained popularity due to the intensive individual construction of residential buildings, as well as the unsatisfactory operation of centralized heating systems in apartment buildings.

In this review, we will take a look at some of the models of this brand, as well as their technical capabilities. Operating instructions will be attached below.

Double-circuit wall heating systems

Variety of models from brand Ariston is large enough, but a review of Ariston gas boilers shows that the most popular is the line of precisely double-circuit units. Here it is assumed both hot water supply and heating of premises from a single energy source. When installed in apartments or private houses with a total area of ​​up to 100 sq. m. the following models are most often purchased, presented in the table below.

Instructions for Ariston double-circuit gas boilers are usually purchased along with all the elements heating system... If you have lost it, it doesn't matter, a little below is presented short instruction to guide you through your day-to-day control operations. It should be noted that, despite the lower gas consumption, the BS24FF model is a more advanced solution precisely in terms of its operational capabilities. So, the instruction.

  1. For the first start-up, you must first make sure that there is air access to the room, ventilation is provided.
  2. Check the water pressure - it should be between 0.6-1.5 bar. Too low pressure requires recharge of the circuit - for this you need to open the valve at the bottom of the boiler.
  3. A frequently falling pressure indicates that there is a water leak from the system. This requires a call to the wizard.
  4. Switching on is simple - by pressing the on / off button.
  5. It is possible to select the "Winter" or "Summer" mode - respectively, heating + DHW or only DHW.
  6. Using the regulation buttons, you can set the coolant temperature from 35 to 82 ° C and hot water- from 36 to 56 ° C.
  7. Switching off the boiler with the on / off button activates the anti-freeze mode. If it is necessary to turn off the boiler completely, turn the external switch to the off position, unplug the boiler from the socket and close the gas cock.

The instruction for the gas boiler Ariston BS24FF notes the differences in the types of combustion chambers. She points out, in particular, that the presence of an open combustion chamber can lead to a lack of oxygen in the room where such a unit operates. Therefore, the useful area of ​​the kitchen, where products with an open combustion chamber are most often installed, should be much larger than in the previous case. Otherwise, it will lead to a malfunction.

The coefficient also decreases slightly useful action... This is mainly due to the fact that boilers with a closed combustion chamber pump the air necessary for the operation of the fuel-burning device directly from the external atmosphere, heating it along the way, which helps to reduce gas consumption.

The instruction of wall-mounted gas boilers Ariston also notes their compactness and ease of installation. At the same time, the Uno 24FF model is intended for relatively small apartments or houses, while more productive options, for example, from the Clas series, are more suitable for installation in large mansions.

Features of the operation of the Uno 24FF model


Instructions gas boiler Ariston Uno considers in detail all issues related to the normal operation of equipment, has the following advantages:

  • advanced design of the heat exchanger with a developed heating area, which is the reason for the high efficiency of the boiler;
  • controllable automation of the work process, which provides for "summer" and "winter" modes of operation of the equipment;
  • blocking the operation of the fuel-burning device, which excludes the failure of the unit in case of interruptions in the supply of water and / or gas;
  • constant control of the temperature of heating water in both circuits thanks to the built-in temperature sensor that controls the operation circulation pump;
  • precise settings of the parameters of the hydraulic and gas system boiler;
  • reliable chimney of the coaxial type, which ensures timely and high-quality removal of combustion products.

The instruction manual for the Ariston gas boiler provides an overview of possible malfunctions, one of the most reliable in its class.

Features of the operation of the BS24FF model


What does the instruction for the Ariston gas heating boiler say? As you can see, this is a more modern constructive solution this type of equipment. Its main advantages are listed below.

  1. Economy, which is most evident when used in apartments or houses of a relatively small area.
  2. Unique hydraulic components of the unit, which ensure complete control of it. In particular, the built-in gas regulator can be set to any power consumption mode.
  3. The affordability of the price creates the opportunity to purchase such a product for almost any potential consumer.
  4. The BS24FF boiler is fully adapted to domestic operating conditions, including low pressure of the energy carrier in the supply networks, possible voltage drops and low outdoor temperatures.
  5. The presence of high-precision diagnostic equipment minimizes the risks of premature failure of the boiler, while expanding its operational capabilities, for example, when installing thermostats in heated rooms.

As a result, reviews about the Ariston gas boiler are mostly positive. It is characterized by a steady demand in the specialized segment of the market for heating equipment for the home. The price range of the products in question is from 16,000 rubles. (for the Uno24FF model) up to 39,000 rubles. (for model BS24FF). The price difference is felt in the structural reliability of the equipment.

Troubleshooting for models of this brand

Despite all the efforts of the manufacturers, periodic repairs of such intensively used products are inevitable. Like other systems of this class, possible problems are considered by the operating manual. For Ariston double-circuit gas boilers, the most common faults are reduced to the following.

  1. Deterioration of gas supply. It is more typical for the gas boiler Ariston Uno - the malfunction manifests itself in the clogging of the gas burner, which operates in less favorable conditions than the fuel combustion device of the BS24FF boiler. This requires thorough cleaning or flushing of the nozzles.
  2. Lack of ignition of the burner when gas is supplied. Due to the presence of control automation, this malfunction is associated with a break in the gas valve windings. This can be checked using the test value of the resistance of the winding of the coils, which is 5.8 kΩ for the primary winding and 19.2 kΩ for the secondary.
  3. Unsatisfactory gas flow through the burner, which causes periodic shutdowns. The cause may be a clogged gas supply valve or a broken diaphragm. Units and parts must be replaced at the service center.
  4. Increased noise during the operation of the boiler (mainly found in products of the Uno24FF model). The reason is the breakage of the modulator spring, which as a result begins to emit vibrating sounds. Depending on the severity of the breakdown, you will have to change either the spring or the modulator itself.




The analysis of these breakdowns indicates that during the operation of the Ariston BS24F gas boiler, malfunctions are more rare. At the same time, in order to extend the service life of the equipment, it is also necessary to periodically check the chimney system, the quality of electrical connections, their grounding, the condition of the chimney pipes, the reliability of ventilation in the room where this equipment is installed, as well as strictly observe the rules of equipment operation.
If these requirements are met, modern and aesthetically pleasing gas boilers Ariston BS24FF and Uno24FF will reliably perform their functions for many years.

Gas boilers Ariston appeared on the Russian heating market among the first. Largely due to its worldwide famous brand, this Italian manufacturer of gas heating equipment quickly managed to "win" a domestic buyer and achieve high sales dynamics.

The Ariston gas boiler, the owners' reviews of which help to better decide on the purchase, we can often find on different sites and in online stores. Modern feature set and good design, not bad specifications and a large selection of models are a clear advantage when buying a device, even though the prices are somewhat overpriced.

But today we will consider not only the pros, but also the disadvantages of Ariston mounted boilers, having studied their structure and features of the models, using the operating instructions, photos, customer and professional reviews.

Lineup of wall-mounted double-circuit gas boilers Ariston

The Italian manufacturer is represented at Russian market a fairly wide range of wall-mounted gas boilers. We can find gas boilers Ariston double-circuit and single-circuit, traditional and condensing, with storage boiler and without it.

In addition, like most competitors, gas boilers heating Ariston are produced with a closed combustion chamber (turbocharged) and with an open one (atmospheric). For devices with forced draft, the chimney outlet is provided horizontally through the wall, having additionally bought for it a special one with a pipe diameter of 60/100 mm.

Gas boilers Ariston: model range


Today, the Italian company produces several modifications of its traditional double-circuit gas boilers:

- Ariston BS 15 FF, 24 FF and 24 II;

- Ariston Cares X 15 CF and 15 FF, 18 FF, 24 CF and 24FF;

- Ariston HS 15 CF and 15 FF, 18 FF, 24 CF and 24FF;

- Ariston Clas X 24 FF, 28 FF and 24 CF;

- Ariston Egis Plus and Premium;

- Ariston Genus X;

- Ariston Alteas X.

The single-circuit gas boiler Ariston with the ability to connect an indirect heating boiler is represented by only one model "Ariston Cares X System" with a capacity of 15 to 32 kW with closed and open combustion chambers.

Ariston double-circuit gas boilers are produced with a capacity of 15, 18, 24 and 28 kW. The most popular modification is a 24 kW device that can heat a house with an area of ​​up to 200-230 m2. Turbocharged boilers are named FF, atmospheric boilers CF.

Features of gas Boiler Ariston Cares X: manual, device

Ariston Cares X 24FF


This model is one of the budget models in the price segment up to 35,000 rubles, and due to this, the most popular, judging by the number of reviews from the owners of the Ariston boiler. But even for a small amount, the buyer receives a modern wall-mounted gas boiler with a nice appearance, button control and LCD display, as well as the entire range of necessary functions.

As in all models of Ariston wall-mounted gas boilers, the "Cares X" series devices are equipped with: a circulation pump of the brand Wilo with automatic air vent and gas valve SIT... In addition, they are equipped with a boiler safety group and an 8 liter diaphragm expansion vessel.

Gas boiler "Ariston Cares X" has two heat exchangers: the main copper with an aluminum coating for the heating circuit and a compact stainless steel secondary for the DHW circuit. The capacity of this secondary heat exchanger for the 24 kW Ariston Cares X 24 FF (CF) models is 13.6 l / min. Consider the device of a double-circuit gas boiler Ariston Cares X 24 FF NG:

Double-circuit gas boiler Ariston


1 - outlet for a coaxial chimney;
2 - pneumatic relay;
3 - collector for condensate;
4 - the main heat exchanger for heating;
6 and 19 - temperature sensors at the inlet and outlet of the heating circuit;
7 - gas burner Polidoro;
8 - ignition electrodes;
9 - secondary heat exchanger for hot water supply;
10 - gas valve SIT;
11 - safety valve for 3 bars;
12 - ignition block;
13 - manometer;
14 - tap for feeding the heating system;
15 - filter;
16 - DHW flow sensor;
17 - circulation pump Wilo;
18 - pressure switch;
20 - three-way valve drive;
21 - burner flame control sensor;
22 - combustion chamber;
23 - expansion tank;
24 - fan (turbine).

Summer-winter mode and room thermostat help reduce gas costs. In summer, the boiler can only work on the DHW circuit, in winter, the device works economically thanks to the modulating gas burner... The room thermostat is not included in the boiler package, but you can always buy it separately.

Boilers of this series have in their device temperature sensors installed on the "supply" and "return", flowing water temperature, flame and draft control sensors. In addition, the devices are equipped with a security system: protection against low water pressure, a function of protection against freezing of the system and its overheating.

The Ariston gas boiler is adapted to Russian conditions, such as voltage drops in the power grid, weak gas pressure and low air temperature outside the window. But, even despite this, the manufacturer himself recommends connecting the boiler through.

This recommendation applies not only to boilers of this brand, but also to other wall-mounted gas boilers of any manufacturer. If the electronic board of the boiler suddenly fails due to a power surge, then this case will not be considered a warranty.

Technical characteristics of a double-circuit gas boiler Ariston Cares X

Ariston gas boiler: technical characteristics


Advantages of gas boilers Ariston:

- a very large selection of models;
- a prestigious global brand;
- Italian assembly;
- two heat exchangers;
- adaptation to Russian conditions.

Disadvantages of gas boilers Ariston:

- overcharge;
- components made in China;
- the main direction of the company is the production of storage water heaters.

Double-circuit gas boilers Ariston

1. Branch pipe of the outlet of combustion products
2. Pressostat
3. Condensate trap
4. Primary heat exchanger
6. Temperature sensor on the supply to the heating circuit
7. Burner
8. Ignition electrodes
9. Gas valve
10. Ignition device
12. Safety valve heating circuit (3 bar)
13. Secondary heat exchanger
14. Drain cock

16. Make-up tap
17. Heating circuit filter
18. Circulation pump with air vent
19. Relay min. Pressure
20. Temperature sensor on the return from the heating circuit
21. Three-way valve drive
22. Flame control electrode
23. Insulating panel of the combustion chamber made of
mineral fiber
24. Combustion chamber
25. Expansion tank
26. Fan
27. Point of analysis of combustion products

Hydraulic circuit

1. Fan
2. Primary heat exchanger
4. Temperature sensor for supply water to the heating circuit
5. Burner
6. Ignition electrodes
7. Gas valve
8. Secondary plate heat exchanger
9. Safety valve 0.3 MPa (3 bar)
11. Automatic bypass
12. Drain cock
13. Make-up tap
14. Heating circuit filter
15. Flow sensor in the DHW circuit
16. Three-way valve
17. Pressure gauge
18. Relay min. Pressure
19. Circulation pump with automatic
air vent
20. Flame control electrode
21. Expansion tank
22. Water temperature sensor on the return line of the circuit
heating
23. Flue gas pressure switch (pressure switch)

Characteristics and operation of the boiler Ariston BS ii 24 ff

The double-circuit gas boiler Ariston BS 24 FF is a versatile and compact mini-boiler room that contains all the necessary components.

A wall-mounted boiler is used for heating small spaces with an area of ​​50-240 m2, in which it is impossible to install a floor heating device, as well as to supply the facility with hot water.

Rice. 1. Control panel of a gas wall-mounted boiler Ariston BS ii 24 ff

1. Green LEDs for temperature and alarm indications, 2. ON / OFF button, 3. Green LED ON / OFF, 4. Pressure gauge (pressure in the heating circuit), 5. Yellow LED for signaling anomalies in the smoke exhaust system, 6. Summer / winter mode switch - Heating system temperature controller, 7. DHW temperature regulator, 8. Socket for programming timer (option), 9. Red LED - dispenser blocking signaling, 10. Reset / Function button chimney cleaning, 11. Red LED for overheating alarm

Rice. 2. General form gas wall-mounted boiler Ariston BS 24 ff

1. Flue gas outlet, 2. Pressostat, 3. Condensate trap, 4. Primary heat exchanger, 5. Overheating thermostat, 6. Temperature sensor in the heating circuit, 7. Burner, 8. Ignition electrodes, 9. Ignition device, 10 Gas valve, 12. Heating circuit safety valve (3 bars), 13. Secondary heat exchanger, 14. Drain valve, 15. DHW flow sensor, 16. Make-up valve, 17. Heating circuit filter, 18. Circulation pump with air vent , 19. Temperature sensor at the return from the heating circuit, 20. Three-way valve drive, 21. Flame control electrode, 22. Thermal insulation panel of the combustion chamber made of mineral fiber, 23. Combustion chamber, 24. Expansion tank, 25. Fan, 26. Point analysis of combustion products

Technical characteristics of the gas boiler Ariston BS ii 24 ff

Nominal thermal power for the heating circuit, no more / no less (Hi) kW - 25.8 / 11.0

Rated thermal power for the heating circuit, no more / no less (Hs) kW - 28.7 / 12.2

Output thermal power (heating mode), no more / no less kW - 24.2 / 9.8

Fuel combustion efficiency (measured at the outlet of combustion products), Hi / Hs% - 94.5

Efficiency at rated power (60/80 ° C), Hi / Hs% - 93.8 / 84.5

Efficiency at 30% of rated power (47 ° C), Hi / Hs% - 93.6 / 84.3

Efficiency on minimum power, Hi / Hs% - 89.2 / 80.3

Heat loss through the chimney with the burner on% - 5.5

Heat loss through the chimney with the burner off% - 0.4

Residual pressure in the circuit Pa - 100

Combustion products temperature (G20) ° C - 105

The amount of combustion products, no more (G20) m3 / h - 56.8

Excess air% - 72

Maximum head loss (dT = 20 ° C) mbar - 200

Residual pressure in the circuit bar - 0.25

Expansion vessel pressure bar - 1

Maximum pressure in the circuit bar - 3

Volume expansion tank l - 8

Water temperature in the heating circuit, no more / no less ° C - 85/35

Water temperature in the DHW circuit, no more / no less ° C - 60/36

DHW flow rate (after 10 minutes at dT = 30 ° C) l / min - 11.3

DHW flow rate at dT = 25 ° C l / min - 13.6

DHW flow rate at dT = 35 ° C l / min - 9.7

Water consumption in the DHW circuit, at least l / min - 1.7

Pressure in the DHW circuit, no more than bar - 7

Voltage and frequency V / Hz - 230/50

Power consumption W - 92

Protection class ° C +5

Weight kg - 30

Dimensions (W x H x D) mm - 400/770/315

Commissioning of gas boiler Ariston BS ii 24 ff

To turn on the boiler, press the on / off button on the control panel.

Power supply - Make sure that the voltage and frequency of the power supply correspond to those indicated on the nameplate of the wall-mounted boiler Ariston BS 24 ff.

Gas supply:

Make sure that the type of gas in the system corresponds to that indicated on the type plate of the boiler.

Open windows and doors.

Make sure there are no open flames or sparks.

Check the gas burner part of the gas wall-mounted boiler Ariston BS ii 24 ff for leaks. To do this, with the gas supply valve closed (off), close and reopen the main gas valve. Within 10 minutes, the meter should not register the gas flow rate.

Filling the heating circuit:

Open the air valves of the radiators of the heating circuit.

Lift the automatic air vent cap of the circulation pump.

Gradually open the boiler make-up valve and close the air valves on the radiators of the heating circuit until water comes out.

When the pressure according to the pressure gauge reaches 0.1 - 0.15 MPa (1 - 1.5 bar), close the boiler feed valve.

First commissioning

Make sure that:

The main gas valve is closed.

The electrical connections are complete. Check again that the green (yellow) wire is connected to a good earth ground.

Use a screwdriver to lift the automatic air vent cap of the circulation pump.

Make sure that the pressure in the system (as indicated by the pressure gauge) is greater than 1 bar.

Turn on the column (by pressing the on / off button) and select the stand-by mode, there is no request for either DHW or the heating system.

Start the evacuation cycle by pressing the MODE button for 10 seconds. The column will begin a purge cycle for approximately 7 minutes.

At the end, check whether the air is completely removed from the heating circuit, if not, repeat the cycle.

Bleed air from radiators.

Open the feed valve cold water, wait until the air is completely removed from the circuit.

The chimney must be of adequate dimensions and free of obstructions for the removal of combustion products.

Make sure the required ventilation openings in the room are open (these should be in a Type B installation).

Open the gas valve, check all seals for leaks: the meter should not show the gas flow rate. If there are leaks, repair them.

Start the Ariston BS 24 ff boiler in winter (heating) or summer (DHW) operating mode.

Automatic forced venting mode

To start the mode, press and hold the MODE button for 10 s. The cycle time is approximately 7 minutes.

To interrupt the cycle, press the MODE button. The cycle can be restarted if necessary.

Make sure that the boiler is in standby mode beforehand, i.e. without supply to the DHW and heating circuits.

Checking gas parameters

Dismantle the front decorative panel and lower the control panel of the Ariston BS ii 24 ff boiler.

Checking the inlet pressure:

Loosen the screw and insert the connecting tube of the pressure gauge into the pressure take-off.

Start the boiler on maximum power in the "Chimney sweep" mode (press the RESET button and hold for 10 s, the display in position 27 shows “L- -“). The gas inlet pressure must correspond to the nominal pressure for the given type of gas.

After 10 minutes or by pressing the button again, the boiler exits the "Chimney sweep" mode.

Checking the maximum power of the gas wall-mounted boiler Ariston BS 24 ff:

To check the maximum power, loosen the screw and connect the pressure gauge tube to the pressure take-off.

Start the boiler in the “Chimney sweep” mode: press the RESET button and hold it for 10 s, the display will show “L- -“; for the boiler to operate at maximum DHW power, press the 1 + button. The display shows “L- -“.

The gas inlet pressure must correspond to that indicated for this type of gas in the summary table of parameters, depending on the type of gas. If not, remove the protective cap and tighten or loosen the adjusting screw.

When finished, tighten the screw and make sure it is tight.

Replace the protective cap on the regulator.

The boiler exits the "Chimney sweep" mode automatically after 10 minutes or immediately after pressing the RESET button.

Checking the minimum power of the gas wall-mounted boiler Ariston BS 24 ff:

To check the minimum power, loosen the screw and connect the pressure gauge tube to the pressure take-off.

Disconnect the combustion chamber expansion tube.

Start the boiler in the "Chimney sweep" mode: press the RESET button and hold for 10 s. The display shows "t". To operate the boiler at minimum power, press the 1 + button.

The display shows "L- -".

Disconnect the wire from the pressure regulator (modulator).

The gas inlet pressure must correspond to that indicated for this type of gas in the summary table of parameters, depending on the type of gas. Otherwise, adjust it with the screw.

When finished, tighten the screw and make sure it is tight.

Connect the wire to the pressure regulator.

Connect the compensator tube.

The Ariston BS ii 24 ff boiler exits from the "Chimney sweep" mode after 10 minutes automatically or immediately by pressing the RESET button.

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

__________________________________________________________________________

_______________________________________________________________________________

__________________________________________________________________________

OPERATION AND REPAIR OF BOILERS

BS gas heating boilers are the optimal equipment for those who understand the economy. The wall-mounted boiler with a capacity of 24 kW for heating and hot water supply is compact in size, light in weight, has two reliable separate heat exchangers and a unique hydraulic group.

The new equipment is distinguished by its affordable price, which makes it an extremely attractive product on the heating market.

Recommended for apartment heating and hot water supply in multi-storey city buildings. Its use will reduce the costs of each consumer for heating (in comparison with the existing central heating supply) by about 2-3 times. Having your own boiler, you decide for yourself when and what temperature in the apartment you need to maintain. Individual comfort, ideal value for money!

Main advantages:

    fully adapted for Russia - operation at reduced gas pressure (up to 5 mbar), low pressure and water consumption;

    resistance to voltage drops;

    built-in condensate trap;

    work at low outdoor temperatures (down to -52 ° C)

    analog control panel with temperature indication

    the possibility of reducing the power for heating (at a constant power for hot water supply) and the function of the turn-on delay

    function of continuous electronic modulation of the burner flame

    functions of protection against frost, scale formation and blocking of the circulation pump and 3-way valve

    self-diagnosis function

    primary heat exchanger made of copper with a protective coating,

    secondary stainless steel plate heat exchanger

    durable stainless steel burner with anti-frequent switch function

    heavy-duty composite hydraulic group, motorized 3-way valve

    2 ultra-precise temperature sensors ntc

    2 filters for mechanical cleaning - in the heating and hot water circuit

    expansion tank 8 l.

    self-diagnosis function

    possibility of connecting t-control and room thermostat